CI1000

CI1000

Features | Capabilities | Specifications
Video Tour (English) | Video Tour (Chinese)

CI1000 Specifications and Options

 

Standard Configuration


The CI1000 System Specifications:

Four axis (XYZtheta), floor mounted robotic table assembly with electronics cabinet. X and Y axis travel of 39.4” by 29.5” and Z-axis travel of 8.9”. Accuracy: ±0.002”.

Includes:
• 1 Introbotix Probe Changer System, consisting of robot
side assembly and probe stand and one probe side
changer assembly
• 1 Introbotix Single-ended Probe Assembly
• 1 Flexible Board Holder
• 1 Guarding with operator accessible areas
• 1 Interface to Tektronix TDR Instrumentation
• 1 Verification Station with 50ohm Airline
• 1 Operator Station with ergonomic arm & flat panel display
• 1 PC controller: 1GB, , 100GB H/D, USB2 Ports
• 1 Camera and Monitor System (Simplify board teach)
• 1 On-site installation and initial set-up (1 day)
• 1 On-site training and operator manual review (2 days)

Software Suite (1 license each):

• CI1000 System Software
• TDR Waveform Viewer™ Generator & Reader
• HFT Report Writer
• HFT CAM Importer

Options:

• Tektronix TDR Digital Oscilloscope
• Tektronix Model #80E04 TDR ElectricalSampling Head Model
• Introbotix Single-ended Probes
• Introbotix Differential Probes
• NIST Standard Verification Station
• Extended warranty, 12 month (labor only)

Specifications


System Rise/Fall Times:

35 picosecond rise time, 50 picosecond fall time

Shortest Measurable Trace Length:

0.5”

Impedance Accuracy:

<0.1 ohms

Repeatability:

0.05 ohms (standard deviation)

Propagation Delay Accuracy:

TDR Jitter: 1 psec ±5PPM of position
TDR Horizontal Accuracy: 1 psec ±1% of the interval

Probe Connections

Two (2), 3.5mm connectors (SMA compatible)

Temperature Operating Temperature Storage

+10°C to +40°C
-22°C to +60°C

Relative Humidity Operating Relative Humidity Storage

20% to 80% at or below 40°C
5% to 90% at or below 60°C

Power Requirements Line voltage Ranges:

90-132 VAC, 180-250 VAC

Line Frequency:

48-440 Hz

CI1000 Specifications and Options

 

Standard Configuration


The CI1000 System Specifications:
Four axis (XYZtheta), floor mounted robotic table assembly with electronics cabinet. X and Y axis travel of 39.4” by 29.5” and Z-axis travel of 8.9”. Accuracy: ±0.002”.

Includes:
• 1 Introbotix Probe Changer System, consisting of robot
side assembly and probe stand and one probe side
changer assembly
• 1 Introbotix Single-ended Probe Assembly
• 1 Flexible Board Holder
• 1 Guarding with operator accessible areas
• 1 Interface to Tektronix TDR Instrumentation
• 1 Verification Station with 50ohm Airline
• 1 Operator Station with ergonomic arm & flat panel display
• 1 PC controller: 1GB, , 100GB H/D, USB2 Ports
• 1 Camera and Monitor System (Simplify board teach)
• 1 On-site installation and initial set-up (1 day)
• 1 On-site training and operator manual review (2 days)

Software Suite (1 license each):

• CI1000 System Software
• TDR Waveform Viewer™ Generator & Reader
• HFT Report Writer
• HFT CAM Importer

 

Options:

• Tektronix TDR Digital Oscilloscope
• Tektronix Model #80E04 TDR ElectricalSampling Head Model
• Introbotix Single-ended Probes
• Introbotix Differential Probes
• NIST Standard Verification Station
• Extended warranty, 12 month (labor only)

Specifications


System Rise/Fall Times:
35 picosecond rise time, 50 picosecond fall time

 

Shortest Measurable Trace Length:
0.5”

 

Impedance Accuracy:
<0.1 ohms

 

Repeatability:
0.05 ohms (standard deviation)

 

Propagation Delay Accuracy:
TDR Jitter: 1 psec ±5PPM of position
TDR Horizontal Accuracy: 1 psec ±1% of the interval

 

Probe Connections:
Two (2), 3.5mm connectors (SMA compatible)

 

Temperature Operating Temperature Storage:
+10°C to +40°C
-22°C to +60°C

 

Relative Humidity Operating Relative Humidity Storage:
20% to 80% at or below 40°C
5% to 90% at or below 60°C

 

Power Requirements Line voltage Ranges:
90-132 VAC, 180-250 VAC

 

Line Frequency:
48-440 Hz